Selecting a Cooling System: Ambient Cooling System | Recirculating Chiller | Liquid-to-Liquid Cooling System | Recirculating Chiller or Liquid-to-Liquid Cooling System | Selecting A Cold Plate Technology | Selecting A Pump | Selecting a Recirculating Chiller | Selecting A Modular Cooling System | Selecting an Liquid-to-Liquid Cooling System | How To Selecting a Heat Exchanger

In order to select the correct heat exchanger or oil cooler, you must first determine the required thermal performance for your application. Use the example shown below:

Step 1: Application Data
Liquid Type: Water
Required Heat Load (Q): 3,300 W (11,263 BTU/Hr)
Temp. of Incoming Liquid (Tliquid in): 80°C (176°F)
Temp. of Incoming Air (Tair in): 21°C (70°F)
Rate of Liquid Flow: 2 gpm (7.6 lpm)



Step 2: Select the heat exchanger product series

Choose an aluminumcopper or stainless steel heat exchanger based on the fluid compatibility. Aluminum tubing is usually used with light oils, or ethylene glycol and water solutions. Copper is normally used with water. Stainless steel is used with deionized water or corrosive fluids.

Step 3: Calculate the initial temperature difference

Subtract the temperature of the incoming air from the temperature of the incoming liquid as it enters the heat exchanger.

ITD = Tliquid in – Tair in
= 80°C – 21°C = 59°C or (176°F – 70°F = 106°F)

Step 4: Calculate the required performance capability (Q/ITD)

Divide the required heat load (Q) by the ITD found above in step 3.

heat exchanger equation 1a

Heat exchanger air flow graph

Step 5: Select the appropriate heat exchanger model

Refer to the thermal performance graphs for the heat exchangers selected (See performance graphs for copper heat exchangers – 6000 series, copper heat exchangers – OEM Coils, stainless steel heat exchangers – Aspen Series, stainless steel heat exchangers – 4000 Series and oil coolers). Any heat exchanger that exceeds 56 W/°C at 2 gpm (using a standard fan) would be acceptable. As shown in the following graph, Lytron’s 6210 exceeds the required performance.

Step 6: Determine the liquid pressure drop

From the data given, we know our pump needs to supply water at 2 gpm. Using the liquid side pressure drop chart for the 6210 curve, the point where a vertical line at the 2 gpm point on the x-axis intersects with the 6210 curve reveals that the liquid pressure drop through the 6210 is 8 psi (0.55 bars). The pump selected must overcome this pressure drop to ensure a 2 gpm flow.

Step 7: Determine the air pressure drop

The vertical line on the thermal performance chart indicates the air flow rate (190 CFM for the Patriot fan) as provided by our standard fans at 60 Hz. The intersection point of this air flow rate and the 6210 graph on the air side pressure drop reveals that the air side pressure drop through the 6210 is 0.24 inches of water (55 pascals).

Heat exchanger liquid side pressure drop graph

Heat exchanger air side pressure drop graph

Releated References:
  • Heat Exchanger
  • U bend Stainless Steel Tube for Heat Exchanger
  • Heat Exchanger Tube
  • Specification/Standards for Heat Exchanger Tubes
  • Finned Tube and Pipe Heat Exchangers
  • Shell Tube and Pipe Heat Exchangers
  • Select Materials for Heat Exchanger Tubes with Substantial Pressure difference
  • The difference between Stainless Steel Tubing and Copper Tubing in Shell and Tube Heat Exchanger
  • Difference in Counter and Parallel Flow Heat Exchanger
  • Aluminum Corrosion Resistance for Cold Plates and Plate-Fin Heat Exchangers
  • Flow arrangement
  • Heat exchangers - Tubes and Pipes Standards
  • Selecting a Heat Exchanger Cooling Liquid
  • Selecting a Heat Exchanger Cooling Air
  • Selecting A Cold Plate Technology
  • Selecting a Cooling System: Ambient Cooling System | Recirculating Chiller | Liquid-to-Liquid Cooling System | Recirculating Chiller or Liquid-to-Liquid Cooling System
  • Selecting A Cold Plate Technology
  • Selecting A Pump
  • Selecting a Recirculating Chiller
  • Selecting A Modular Cooling System
  • Selecting an Liquid-to-Liquid Cooling System
  • How To Selecting a Heat Exchanger
  • How to Boost the Efficiency of Heat Exchanger
  • Comparison of Heat Exchanger Types
  • Parallel and Counter Flow Design
  • Direct contact heat exchanger

  • Types of heat exchangers
    Shell and tube heat exchanger
    Plate Heat Exchanger - Efficiency and Flexibility
    U Tube heat exchanger
    Regenerative heat exchanger
    Adiabatic wheel heat exchanger
    Plate fin heat exchanger
    Fluid heat exchangers
    Phase-change heat exchanger
    Parallel Flow Heat Exchanger
    Counter Flow Heat Exchanger
    Cross Flow Heat Exchanger
    Spiral heat exchangers
    Shell and Coil Heat Exchangers
    Brazed Heat Exchangers - Advantages | Applications | Specifications
    Titanium Heat Exchanger
    Plate and Shell Heat Exchanger - Applications | Specification
    Block Welded Heat Exchanger - Applications | Specification


    Heat Transfer | Forms | Effects | Conduction | Convection | Radiation | Heat Exchanger
    Metal Glossary | Metals Definitions | Heat Treatment of Metals | Passivation | Annealing | Quenching | Tempering | Heat Treatment of Steel | Heat Treating Definition | Heat Treating Stainless Steel | Technic of Metals Heat Treatment | Elements in Annealed State | Bright Anneaing | ASTM A380 | ASTM A967 | EN 2516 | 304 | 304L | 321 | 316L | 317L | 310S | 410 | 410S


  • Construction
  • Self cleaning
  • Applications
  • Selection
  • Pre Heater
  • Radiator
  • Air Conditioner Evaporator and Condenser
  • Large Steam System Condensers


  •     © Copyright Reserved   Home  |  Site Map   |  Links  |  Directory  |  Advertise  |   Heat  |  Tools  |  Standard  |  Pressure  |  Hardness  |  Surface   |  Metal Engineering
         E-mail: sales@stainless-steel-tube.org                                        
        Stainless Steel Pipe | Stainless Steel Tube | Stainless Steel Tubing | Heat Exchanger Tube | Duplex Stainless Steel Pipe | U Bend Tube