Selecting a Cooling System: Ambient Cooling System | Recirculating Chiller | Liquid-to-Liquid Cooling System | Recirculating Chiller or Liquid-to-Liquid Cooling System | Selecting A Cold Plate Technology | Selecting A Pump | Selecting a Recirculating Chiller | Selecting A Modular Cooling System | Selecting an Liquid-to-Liquid Cooling System | How To Selecting a Heat Exchanger

Selecting the proper recirculating chiller is a function of four factors:

Chiller Kodiak RC022 - RC045 Thermal Performance Curve

Figure 1: Recirculating Chiller RC022-RC045 Thermal Performance Curve

Recirculating Chillers Positive Displacement Pumps Graph

Figure 2: Recirculating Chiller System Pump Curve

  1. The heat load generated by the device being cooled (Q)
  2. The maximum acceptable temperature of the fluid exiting the heat source (TOUT)
  3. Available fluid flow rate (equation symbol )
  4. Ambient operating conditions

Often, an equipment manufacturer will specify the set point temperature and flow rate of the required chiller. In this case, selecting a recirculating chiller is simple. Simply mark the intersection of the desired cooling capacity and the set point temperature on the chiller graph. Any chiller with a performance curve above or equal to this point will provide enough capacity. Next, use the pump graph to select a pump for your recirculating chiller which meets the desired flow rate.

Example 1:

A chiller needs to supply 2 gpm at 20°C to an x-ray tube that generates 2,000 W of heat. The power supply is 60 Hz. Marking this point on the chiller graph we can see that an RC022 would be an appropriate choice. From looking at the pump curves we see that a BE pump would provide the necessary flow rate.

If the Heat Load (Q) is known, but the Flow Rate is unknown, the following equation can be used to determine the required flow rate.

equation 1

Example 2:

A laser head generates 2,000 Watts (6,824 BTU/Hr) of heat. The fluid temperature must not exceed 20°C (68°F). With a cooling fluid of water, 60 Hz power, at 20°C ambient, what is the appropriate recirculating chiller?

Using the thermal performance graphs (fig 1), draw a horizontal line at the required heat load (2000 W). As shown, the RC022 would match this requirement at 13°C (55°F). This is TIN (the temperature exiting the recirculating chiller). Therefore, the calculation then becomes:

equation 2

Next, determine if the recirculating chiller can meet the required flow rate. As shown on the system pump graph (fig 2), the 1.3 gpm positive displacement pump would more than satisfy the flow requirement.

Releated References:
  • Heat Exchanger
  • U bend Stainless Steel Tube for Heat Exchanger
  • Heat Exchanger Tube
  • Specification/Standards for Heat Exchanger Tubes
  • Finned Tube and Pipe Heat Exchangers
  • Shell Tube and Pipe Heat Exchangers
  • Select Materials for Heat Exchanger Tubes with Substantial Pressure difference
  • The difference between Stainless Steel Tubing and Copper Tubing in Shell and Tube Heat Exchanger
  • Difference in Counter and Parallel Flow Heat Exchanger
  • Aluminum Corrosion Resistance for Cold Plates and Plate-Fin Heat Exchangers
  • Flow arrangement
  • Heat exchangers - Tubes and Pipes Standards
  • Selecting a Heat Exchanger Cooling Liquid
  • Selecting a Heat Exchanger Cooling Air
  • Selecting A Cold Plate Technology
  • Selecting a Cooling System: Ambient Cooling System | Recirculating Chiller | Liquid-to-Liquid Cooling System | Recirculating Chiller or Liquid-to-Liquid Cooling System
  • Selecting A Cold Plate Technology
  • Selecting A Pump
  • Selecting a Recirculating Chiller
  • Selecting A Modular Cooling System
  • Selecting an Liquid-to-Liquid Cooling System
  • How To Selecting a Heat Exchanger
  • How to Boost the Efficiency of Heat Exchanger
  • Comparison of Heat Exchanger Types
  • Parallel and Counter Flow Design
  • Direct contact heat exchanger



  • Types of heat exchangers
    Shell and tube heat exchanger
    Plate Heat Exchanger - Efficiency and Flexibility
    U Tube heat exchanger
    Regenerative heat exchanger
    Adiabatic wheel heat exchanger
    Plate fin heat exchanger
    Fluid heat exchangers
    Phase-change heat exchanger
    Parallel Flow Heat Exchanger
    Counter Flow Heat Exchanger
    Cross Flow Heat Exchanger
    Spiral heat exchangers
    Shell and Coil Heat Exchangers
    Brazed Heat Exchangers - Advantages | Applications | Specifications
    Titanium Heat Exchanger
    Plate and Shell Heat Exchanger - Applications | Specification
    Block Welded Heat Exchanger - Applications | Specification


    Heat Transfer | Forms | Effects | Conduction | Convection | Radiation | Heat Exchanger
    Metal Glossary | Metals Definitions | Heat Treatment of Metals | Passivation | Annealing | Quenching | Tempering | Heat Treatment of Steel | Heat Treating Definition | Heat Treating Stainless Steel | Technic of Metals Heat Treatment | Elements in Annealed State | Bright Anneaing | ASTM A380 | ASTM A967 | EN 2516 | 304 | 304L | 321 | 316L | 317L | 310S | 410 | 410S


  • Construction
  • Self cleaning
  • Applications
  • Selection
  • Pre Heater
  • Radiator
  • Air Conditioner Evaporator and Condenser
  • Large Steam System Condensers


  •     © Copyright Reserved   Home  |  Site Map   |  Links  |  Directory  |  Advertise  |   Heat  |  Tools  |  Standard  |  Pressure  |  Hardness  |  Surface   |  Metal Engineering
         E-mail: sales@stainless-steel-tube.org                                        
        Stainless Steel Pipe | Stainless Steel Tube | Stainless Steel Tubing | Heat Exchanger Tube | Duplex Stainless Steel Pipe | U Bend Tube